LNG - L-CNG – The Standard Dispenser
FAS LNG Standard Dispenser
- LNG dispensing at 8 bar, -130°C
- EU-declaration of conformity and ATEX-label
- MID-certificate – EU-type examination certificate (NMi)
- Maxium flow rate: 100kg/minMicro Motion Elite CMF100 mass flow metre with OIML R81 & R117-1 certificate – LNG measurement error of 0,35%
- Micro Motion Elite CMF050 mass flow metre with OIML R81 & R117-1 certificate – BOG measurement error of 0,35%
- EAS2 processor with OIML R81, R117-1 & R139 certificate (NMi)
- Communication with mass flow metre via Modbus
- Communication with payment unit or payment system via EAS1 protocol
- Communication with PLC via Modbus for the analysis of dispenser data
- Graphic display with display of price per kg, dispensing per kg and lump sum price
- Storing of last 150 deliveries & 250 error codes - Volatge: 230V AC, 50Hz, 300W
- Dispenser and EAS2 processor in protection category: IP54
- Base frame out of stainless steel, primed and powder-coated
- Automatic regulation of cooling, filling and venting of the tank with pneumatic valves
- Measurement of fillig pressure and temperature
- Flexible filling hose 1“, equipped with burn protection and breakaway coupling
- Flexible venting hose ½“, equipped with burn protection and breakaway coupling
- Filling connection and venting connection by JC Carter or Macrotech
- Configurable key as deadman´s switch and delivery notice
- Emergency stop button
- Ground terminal
- Compressed air piston
Optionally available:
- MODULE D MID certificate: Based on the quality assurance during the production process including the inspection of dispensers to ensure techncal measurement requirements
- EAS2 LON MODULE – communication to pay terminal IFSF-LON protocol
- ATEX BOX KIT EAS2 ExnA E30 LNG – ready for installation in ATEX Zone 2
- Filling kit for single hose refuelling – filling adapter for Volvo trucks
- Breakaway coupling LNG 1“ ANSI 300 PN 40
- Breakaway coupling LNG 1/2“, ANSI 30, PN 40