LNG/L-CNG – The high-pressure Vaporiser
The image shows a FAS LNG evaporator plant during operation. Redundand systems are essential to counteract unavoidable icing.
The atmospheric high-pressure vaporiser is powered by LNG by the high-performance pump under a condition of approximately 300 bar. The LNG vaporises and is beeing further transported to the safety panel.
Details
- Outer material: Al 6060 Aluminium (wing tube)
- Material (in contact with LNG): Aisi304 L stainless steel
- Design pressure: 300 bar
- Design temperature: -196°C / +60°C
- Dimensions: width x depth x higth mm
- Working cycle: 8 hours at 20°
- Ambient temperature of approximately 15°C initial temperature, at a relative humidity of 70%